Data Center
Data Center is the most vital part of the overall infrastructure network because of this is where servers and data centralized. Development of Data Center must take into consideration all aspects as to keep it safe and to provide uninterrupted service to all users who need access to data in the network.
Data Center is the most vital part of the overall infrastructure network because of this is where servers and data centralized. Development of Data Center must take into consideration all aspects as to keep it safe and to provide uninterrupted service to all users who need access to data in the network.
PT. Revo Solusindo provides Data Center Services that include Design, Built, Implementation and Migration for all the equipment. In making design, PT. Revo Solusindo consider components according to Tier 1-4 are:
- Ideal Data Center location
- Design Data Center Layout for the most efficient movement of people and changing of IT Equipment. Design must be scalable
- Design includes cooling system located in the Data Center. Using a Precision Cooling system (PAC), efficient and in accordance with ASHRAE standards. Cooling should be focused on the equipment and not the room itself. To achieve this consideration the cool air from PAC and hot air from the devices in racks should be separated in cool aisle and hot aisle which cool air from PAC will flow in the cool aisle and Hot air from device will return to the PAC intake thru hot aisle.
- Installation of Power to be independent (independent and integrated with building a power plant) and the backup generator with the precision and Redundant UPS (according to TIER)
- Data Cable Installation in accordance with the standard EIA / TIA 942 and 568 and also adapted to the Design of Network Topology company
- Total protection against fire (Fire System) but also remains safe to humans (corresponding environments (ZERO Global Warming). Have to be considered to secure the IT equipment itself. Including installation of Very Early Smoke Detection Apparatus (VESDA) to smoke any small the potential for fire.
- Security System consists of CCTV and Access Control where everything must be IP based devices so that can be integrated with the LAN and the existing control system at the NOC (Network Operation Center).
- Environment Monitoring System (EMS) which will be monitored from the NOC all equipment Data Center page on (POWER PLN, GENSET, UPS, PAC, Fire System). EMS Alert should also be able to provide such SMS or E-mail to a designated person so that can provide immediate and permanent action early. All equipment must have a data interface (both IP and Analog / Dry Contact) to send status and the damage done to the EMS Devices.
All the design will be presented in both 2-dimensional layout or 3 dimensions, including video animations of all space and equipment such Data Center.